Daikin FTXR42EV1B9 Specifikace Strana 21

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 167
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 20
SiBE04-624_B Indoor Unit
Printed Circuit Board Connector Wiring Diagram 11
A2P: Display PCB
Caution Replace the PCB if you accidentally cut the jumpers other than JA.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
A3P: Signal
Receiver /
Transmitter PCB
1) S56 Connector for control PCB
2) S57 Connector for signal receiver / transmitter PCB
3) S63 (H1P) Connector for LED PCB (multi monitor)
4) JA Address setting jumper
*Refer to page 150 for detail.
5) SW1 (S1W) Forced cooling operation [ON/OFF] button
*Refer to page 147 for detail.
6) LED2 (H2P) LED for timer (yellow)
7) LED3 (H3P) LED for moisture operation (green)
JA S56
SW1
LED2
LED3
S57
S63
3P163884-2
1) S58 Connector for display PCB
S58
3P163884-2
Zobrazit stránku 20