Daikin RZR42PVJU Instalační manuál Strana 1

Procházejte online nebo si stáhněte Instalační manuál pro Split-systém klimatizace Daikin RZR42PVJU. Daikin RZR42PVJU Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 18
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
MODELS
RZR36PVJU
RZR42PVJU
RZQ30PVJU9
RZQ36PVJU9
RZQ42PVJU9
Read these instructions carefully before installation.
Keep this manual in a handy place for future reference.
This manual should be left with the equipment owner.
Lire soigneusement ces instructions avant l’installation.
Conserver ce manuel à portée de main pour référence ultérieure.
Ce manuel doit être donné au propriétaire de l’équipement.
Lea cuidadosamente estas instrucciones antes de instalar.
Guarde este manual en un lugar a mano para leer en caso de
tener alguna duda.
Este manual debe permanecer con el propietario del equipo.
SPLIT SYSTEM Air Conditioners
INSTALLATION MANUAL
English
Français
Español
00_CV_3PN07193-7H.fm Page 1 Saturday, December 25, 2010 1:03 PM
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - INSTALLATION MANUAL

MODELSRZR36PVJURZR42PVJURZQ30PVJU9RZQ36PVJU9RZQ42PVJU9Read these instructions carefully before installation.Keep this manual in a handy place for futu

Strany 2 - 1. SAFETY CONSIDERATIONS

9 English• Be careful not to let the field piping come into contact with the compres-sor terminal cover.Adjust the height of the insulation material o

Strany 3 - 2. INTRODUCTION

English 10• If the outdoor unit is not in operation and the total amount cannot be charged, follow the procedures for additional refrigerant charge sh

Strany 4 - LOCATION

11 EnglishCAUTION<To electrician>• Do not operate the air conditioner until the refrigerant piping work is completed. (Operating the air condit

Strany 5 - English 4

English 127-3 Power supply wiring connection procedureWARNING• Never connect power supply wiring to the terminal block for remote controller wiring as

Strany 6 - 5 English

13 English7-4 Transmission wiring connection procedure• If an excessive force is applied while connecting a cable to the terminal block on the PC boar

Strany 7 - English 6

English 149-1 Power on and check operation• Make sure to perform the check operation after installation. (If the air conditioner is operated using the

Strany 8 - 6. REFRIGERANT PIPING WORK

15 English(Check a malfunction code in the remote controller connected to the indoor unit.)• There might be a problem with the connection or transmiss

Strany 9 - English 8

English 16NOTE• Where a single refrigerant facility is divided into 2 entirely indepen-dent refrigerant systems then use the amount of refrigerant wit

Strany 10 - 6-5 Heat insulation of piping

(1101) HT3PN07193-7H EM10A07000_CV_3PN07193-7H.fm Page 2 Saturday, December 25, 2010 1:03 PM

Strany 11 - 7. ELECTRIC WIRING WORK

1 EnglishSPLIT SYSTEM Air Conditioners Installation manualCONTENTS1. SAFETY CONSIDERATIONS... 12. INTRO

Strany 12 - 11 English

English 2• Heat exchanger fins are sharp enough to cut.To avoid injury wear glove or cover the fins when working around them.• Install drain piping to

Strany 13 - English 12

3 English2-3 Electrical specifications(∗<c> in the table indicates the operating condition (shown in the previ-ous figure).)2-4 AccessoriesConfi

Strany 14 - 9. TEST RUN PROCEDURE

English 4(5) The inverter type air conditioner may cause noise in electric products.When selecting an installation location, keep sufficient dis-tance

Strany 15 - English 14

5 English(2)When two or more outdoor units are installed side by side• When an obstruction is present also in the upward area(1)When one outdoor unit

Strany 16 - 15 English

English 6<Pattern 2>When an obstruction on the air outlet side is lower than the outdoor unit (There is no restriction in the height of obstruct

Strany 17 - English 16

7 English(E) When outdoor units are installed in rows (on the rooftop, etc.)(1)When one outdoor unit is installed in each row(2)When two or more outdo

Strany 18 - (1101) HT

English 8NOTE• Maximum piping length between the outdoor and indoor unit is 230ft.• Installation tools:Make sure to use installation tools (gauge mani