FH(Y)C-B7
4-Way Blow Ceiling
Mounted Cassette
technical data
Split
Sky Air
air conditioning systems
Zobrazit stránku 0
1 2 3 4 5 6 ... 29 30

Shrnutí obsahu

Strany 1 - Mounted Cassette

FH(Y)C-B74-Way Blow CeilingMounted Cassettetechnical data SplitSky Airair conditioning systems

Strany 2 - Split - Sky Air

ELECTRICAL SPECIFICATIONSFor indoor units only: FHYC35B7V1 FHYC45B7V1 FHYC60B7V1CURRENT Nominal running currentcoolingASee chapter R(E)Y: Electrical d

Strany 3 - TABLE OF CONTENTS

3Dimensional drawingsFH(Y)C35-71B7view A680 Suspension positionB view780 (Suspension position)860∼890 (Ceiling opening)Note:1. Location of unit’s name

Strany 4 - 213r xq8

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeHeat exchangerLiquid pipe connect

Strany 5

5Wiring diagrams3TW22836-1FHYC35-125B733H Float switchA1P Printed circuit boardC1R Capacitor (M2F)HAP Light emitting diode (service monitor green)HBP

Strany 6

6Sound levels6-1Sound level dataOctave band sound pressure levelOctave band sound pressure levelModelSound pressure levelMeasuring locationSound power

Strany 7

7Air flow patterns & branch duct connections7-1Air flow patternsFH(Y)C35B7V1Heating - air velocity distribution4-way discharge, air flow direction

Strany 8

FH(Y)C45B7V1Heating - air velocity distribution4-way discharge, air flow direction: downFH(Y)C45B7V1Heating - air temperature distribution4-way discha

Strany 9

FH(Y)C60,71B7V1Heating - air velocity distribution4-way discharge, air flow direction: downFH(Y)C60,71B7V1Heating - air temperature distribution4-way

Strany 10 - Specifications

FHYC100B7V1Heating - air velocity distribution4-way discharge, air flow direction: downFHYC100B7V1Heating - air temperature distribution4-way discharg

Strany 11 - Dimensional drawings

FHYC125B7V1Heating - air velocity distribution4-way discharge, air flow direction: downFHYC125B7V1Heating - air temperature distribution4-way discharg

Strany 12 - Piping diagrams

Split - Sky AirEEDE02-1/1A • 10/2002Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumInternet: http://www.daikineurop

Strany 13 - Wiring diagrams

7Air flow patterns & branch duct connections7-2Branch duct connectionsFH(Y)C-B1 branch duct - 3 way blowDischarge grill: K-DGSC4B (connection: dia

Strany 14 - Sound levels

FH(Y)C-B1 branch duct - 3 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flixible duct: K-FDK154B (connection: diameter 200mm, length:

Strany 15 - Air flow patterns

FH(Y)C-B1 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 150mm)Flexible duct K-FDK154B (connection: diameter 150mm, length: 4

Strany 16 - 4D024117

FH(Y)C-B1 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flixible duct: K-FDK154B (connection: diameter 200mm, length:

Strany 17 - 4D024118

FH(Y)C-B2 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 150mm)Flexible duct K-FDK154B (connection: diameter 150mm, length: 4

Strany 18 - 4D024119

FH(Y)C-B2 branch duct - 2 way blowDischarge grill: K-DGSC4B (connection: diameter 200mm)Flixible duct: K-FDK154B (connection: diameter 200mm, length:

Strany 19 - 4D024120

8Accessories8-1Standard accessoriesCheck if the following accessories are included with your unit.Clamp1 pc.Also used as packing materialPaper pattern

Strany 20 - Branch duct connections

FH(Y)C-BFresh air intake kit1. Option kits KDDJ55B160, KDDJ55B160K,KDDJ55B160FFollowing restrictions must be kept:1. Maximum 20% of the nominal indoor

Strany 21

9Control systems9-1Wired remote controlBRC1C517Fig. 1BRC1C5176.5 x 9 (Round end slit)Fig. 2Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (R

Strany 22

Name and function of each switch and display onthe remote control1ON/OFF BUTTONPress the button and the system will start. Press the button again and

Strany 23

TABLE OF CONTENTSFH(Y)C-B71 Features ... 22 Specifications...

Strany 24

10Centre of gravityFH(Y)C-BModel A BFH(Y)C35-71B 230 90FHYC100,125B 288 1204TW22839-2FH(Y)C-BModel Safety devices 35 45 60 71 100 125FHYC∼BPC board fu

Strany 25

1Features+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Fits flush into each ceiling+ Can be installed in both new and e

Strany 26 - Accessories

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHC35B7V15 FHC45B7V15 FHC60B7V15NOMINAL INPUT Cooling kW 0.14 0.14

Strany 27

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHYC71B7V1 FHYC100B7V1 FHYC125B7V1NOMINAL INPUT Cooling kW 0.161 0.204 0.238For c

Strany 28 - Control systems

ELECTRICAL SPECIFICATIONSFor indoor units only: FHC35B7V1 FHC45B7V1 FHC60B7V1CURRENT Nominal running current ASee chapter R: Electrical dataMax. runni

Strany 29

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHYC35B7V1 FHYC45B7V1 FHYC60B7V1NOMINAL INPUT Cooling kW 0.14 0.14 0.161Heating k

Strany 30 - Safety device settings

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FHYC71B7V1 FHYC100B7V1 FHYC125B7V1NOMINAL INPUT Cooling kW 0.161 0.204 0.238Heati