RQYQ 140 RXYQQ8-12T
RXYQQ14-
20T
2-module
systems
3-module
systems
Multi-module connection kit (obligatory) - Connects multiple modules into a single refrigerant system - - -
BHFQ22P1007 BHFQ22P1517
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain water from all bottom plate
outlets into a single outlet. In cold areas should be heated by a eld-supplied heater to prevent drain water from freez-
ing in the drain pan.
KWC26B160 - - - -
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in extremely cold and humid climates -
EKBPH012T*
+ EKBPHP
-
CBT*
EKBPH020T*
+ EKBPHP-
CBT*
- -
External control adaptor for outdoor unit - Allows to activate Low Noise Operation and three levels of Demand Limit
-
ing via external dry contacts. Connects to the F1/F2 communication line and requires power supply from an indoor
unit*, BSVQ box, or VRV-WIII outdoor unit.
DTA104A53/61/62
For installation into an indoor unit: exact adaptor type depends on type
of indoor unit. See Options & Accessories of indoor units
BHGP26A1 - Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as
standard, or expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor
unit PCB, for installation in the outdoor unit.
1 kit per
system
1 kit per
system
KRC19-26A - Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat
Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box.
1 kit per
system
1 kit per
system
BRP2A81 - Cool/heat selector PCB (required for VRV IV) -
KKSA26A560* - Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and Heater tape kit
are combined)
-
KJB111A - Installation box for remote cool/heat selector KRC19-26A
1 kit per
system
1 kit per
system
EKPCCAB1 - VRV congurator -
DTA104A61/62* - Demand PCB allowing external input to limit power consumption
-
KKSB2B61* - Demand PCB mounted plate. Needed to mount Demand PCB for some outdoor units.
- -
- -
Accessories
RQEQ 140~212
2-module
systems
3-module
systems
4-module
systems
Multi-module connection kit (obligatory) - Connects multiple modules into a single refrigerant system - BHFP26P36C BHFP26P63C BHFP26P84C
Central drain pan kit
Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single
outlet. In cold areas should be heated by a eld-supplied heater to prevent drain water from freezing in the drain pan.
KWC26B160 1 kit per module 1 kit per module 1 kit per module
External control adaptor for outdoor unit
Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Connects to the
F1/F2 communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit.
DTA104A53/61/62
For installation into an indoor unit: exact adaptor type depends on type of
indoor unit.
See Options & Accessories of indoor units
BHGP26A1
Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as standard, or
expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor unit PCB, for
installation in the outdoor unit.
1 kit per system 1 kit per system 1 kit per system
Heat Recovery
OUTDOOR SYSTEM
RQCEQ280P RQCEQ360P RQCEQ460P RQCEQ500P RQCEQ540P RQCEQ636P RQCEQ712P RQCEQ744P RQCEQ816P RQCEQ848P
System Outdoor unit module 1 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ212P
Outdoor unit module 2 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ180P RQEQ212P
Outdoor unit module 3 RQEQ180P RQEQ212P RQEQ180P RQEQ212P
Outdoor unit module 4 - RQEQ212P
Capacity range HP 10 13 16 18 20 22 24 26 28 30
Cooling capacity Nom. kW 28.0 36.0 45.0 50.0 54.0 63.6 71.2 74.4 81.6 84.8
Heating capacity Nom. kW 32.0 40.0 52.0 56.0 60.0 67.2 78.4 80.8 87.2 89.6
Power input -
50Hz
Cooling Nom. kW 7.04 10.3 12.2 13.9 15.5 21.9 21.2 23.3 27.1 29.2
Heating Nom. kW 8.00 10.7 13.4 14.7 16.1 17.7 20.7 21.2 23.1 23.6
EER 3.98 3.48 3.77 3.61 3.48 2.90 3.36 3.19 3.01 2.90
COP 4.00 3.72 3.89 3.80 3.72 3.79 3.80 3.81 3.77 3.79
Maximum number of connectable indoor units 21 28 34 39 43 47 52 56 60 64
Sound pressure level
Cooling Nom. dBA 57 61 62 63 64 63 64 65 66
Piping
connections
Liquid OD mm 9.52 12.7 15.9 19.1
Gas OD mm 22.2 25.4 28.6 34.9
Discharge gas OD mm 19.1 22.2 25.4 28.6
Piping length OU - IU Max. m 120
Total piping length
System Actual m 300
Level dierence OU - IU m 50 (outdoor unit in highest position)
Current - 50Hz Maximum fuse amps (MFA) A 30 40 50 60 70 80 90
OUTDOOR UNIT MODULE RQEQ140P RQEQ180P RQEQ212P
Dimensions Unit
HeightxWidthxDepth
mm 1,680x635x765
Weight Unit kg 175 179
Sound pressure level
Cooling Nom. dBA 54 58 60
Operation range Cooling Min.~Max. °CDB -5~43
Heating Min.~Max. °CWB -20~15
Refrigerant Type R-410A
Power supply Phase/Frequency/Voltage Hz/V 3~/50/380-415
RQCEQ-P