FDYMP-L7
Concealed Ceiling Unit
technical data
Split
Sky Air
air conditioning systems
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - Concealed Ceiling Unit

FDYMP-L7Concealed Ceiling Unittechnical data SplitSky Airair conditioning systems

Strany 2 - Split - Sky Air

5Wiring diagrams2TW25046-1AFDYMP71∼125L7A1P Printed circuit boardT1R Power supply transformer (transformer 220-240V/218V)C1R Capacitor (fan)F1T Therma

Strany 3 - TABLE OF CONTENTS

6Sound level6-1Sound level dataSound pressure level (dB)Sound pressure level (dB)Octave band center frequency (Hz) Octave band center frequency (Hz)Oc

Strany 4 - Optional

6Sound level6-3Sound power spectrumFDYMP71L7Octave band center frequency (Hz)Octave band center frequency (Hz)Sound power level (dB)Sound power level

Strany 5 - Specifications

7Fan characteristics3TW25048-1FDYMP71L7FDYMP100L73TW25058-1FDYMP125L73TW25068-1ESP (Pa)Air flow (m3/min)Air flow (m3/min)ESP (Pa)ESP (Pa)Air flow (m3/

Strany 6

8Accessories8-1Optional accessoriesWire specificationsConnector (White)Whiteconnect to indoor PCB (X40A)connect to on/off switchAWG24 0.22mm2White* In

Strany 7

9Control systems9-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BRC1

Strany 8 - Dimensional drawings

10Center of gravityFDYMP71-125L7Model Safety devices 71 100 125FDYMP Fan motor thermal fuse (°C) 152±2 152±2 152±23TW21009-2C11Safety device settingsM

Strany 9 - Piping diagrams

12Installation instructionsPreparations before installing Selecting installation siteHow to clean the air filterNames and functions of partsService of

Strany 10 - Wiring diagrams

Only for 125 classFilter holding plateNOTES1 Filter must slide in the filter fixing plates (see detail A)2 Filter holding plate must be mounted correc

Strany 11 - Sound level

Split - Sky AirEEDE03-1/2 • 03/2003Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumInternet: http://www.daikineurope

Strany 12

TABLE OF CONTENTSFDYMP-L1 Features ... 22 Specifications...

Strany 13 - Fan characteristics

1Features+ Lightweight and compact: the depth of the unit is just 279mmfor all capacity sizes.+ Both discharge and suction ducts can be easily connect

Strany 14 - Accessories

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FDYMP71L7V1 FDYMP100L7V1 FDYMP125L7V1NOMINAL INPUT Cooling kW - -

Strany 15 - Control systems

TECHNICAL SPECIFICATIONSFor indoor units only:INDOOR UNITS FDYMP71L7V1 FDYMP100L7V1 FDYMP125L7V1DIMENSIONS Unit H mm 279W mm 987 1,387D mm 750WEIGHT U

Strany 16 - Safety device settings

ELECTRICAL SPECIFICATIONSFor indoor units only: FDYMP71L7V1 FDYMP100L7V1 FDYMP125L7V1CURRENT Nominal running currentcooling/heatingA See chapter RP-L7

Strany 17 - Installation instructions

3Dimensional drawingsFDYMP71-100L7view A960 (Suspension position)view BNotes:1. Refer to ’outlook drawing for installing optional accessories’ when in

Strany 18

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeHeat exchangerRefrigerant flowCoo